• Home
  • /Wattmeters & Power Analyzers

Wattmeters & Power Analyzers

 

Low Cost Wide-Range Power Analyzer

Model 2105

Spectrum Power Analyzers

Models 2410 & 2430

Single to Six-Phase Power Analyzer

Model 2800 Series

Energy Analyzer Datalogger

Model 3030A

  • Up to 20 Amps/phase direct
  • Expandable to 1000 amps
  • Wide Voltage Ranges 30V, 150V, 300V, 600V
  • True Power Measurements, VIcos Ø
  • High Accuracy Measurement: 0.15% DC to 5KHz
  • Bandwidth~ DC, 20 Hz to 50 KHz
  • Zero to Unity Power Factor Response
  • Accurate Regardless of Waveform Distortion
  • Certificate of Traceability N.I.S.T.
  • Single-Phase(1Ø) and Three-Phase(3 Ø)
  • The Three-Phase Power Analyzer puts up to 32 measured values on the screen.
  • Broad bandwidth: DC-300kHz
  • Wide input range (0.3V – 1000V, 15mA – 40A).
  • Suitable for frequency inverter drivers
  • Harmonics Analyzer 1-99, Bar charts
  • 0.1% or 0.05% accuracy
  • True Power Measurements, VIcos Ø
  • Wide input range (0.3V – 1000V, 15mA – 40A).
  • RS232 or IEEE 488, Centronics’ printer compatible
  • Available as 1-, 2-, 3-, 4-, 5-, 6-phase instrument
  • Highest precision available: 0.02% reading + 0.02% range
  • 18 bit resolution. High accuracy at 10% full scale
  • Wide angle, touch-screen TFT color display (800 x 480 pixels)
  • Simple to operate, most settings in 2 steps (2 touches)
  • Standard-, logging-, Transient-, Power-Speed measure functions
  • Very fast data transfer; up to 3400 values per second
  • High DC precision for solar applications
  • 4 current inputs: 1mA-1A, 15mA- 5A, 1A- 50A, Shunt
  • Voltage Ranges: 0.3V to 1000V
  • Interfaces: Ethernet, RS-232 I USB, IEEE-488, Process
  • Interface commands for fast data transmission
  • Operating software under Windows
  • Reasonably priced by virtue of smart design
  • Simple servicing, modular concept, pre-calibrated inputs
  • Optional high precision, broadband, current sensors
  • Optional 30A coaxial shunt (current viewing resistors)
  • 1G Byte Memory for storing measurement data
  • 6 analog inputs and 2 frequency inputs, 12 analog outputs
  • Power Mains Data Logger
  • Accommodates Single Ø and 3-wire Delta and 4-wire Wye
  • 3 Voltage Channels ~ 4 Current channels
  • Accommodates inputs from CT’s to 600A (6 F.S. Auto-Ranges)
  • Accommodates inputs of 600VAC direct or up to 15KVAC from PT’s
  • 100 Measurements each second
  • Monitors and records Power Demands or Disturbances
  • True RMS VA (apparent power) and True Power, VIcos Ø -Maximum, minimum, average and present value for each, regardless of wave shape or distortion level
  • 4 Categories of Voltage and Current Measurements
  • 4 Categories of Power Factor Measurements
  • Power Duty Cycle – Average “On” Time – Power Cycles-Estimated power cycles, Peak Demand Period
  • Transient/Swell/Sag Detection 5 Categories
  • Real Time Clock/Calendar – Displays present and elapsed time of monitoring