2400 Series Wideband Spectrum Power Analyzers

Models 2410 and 2430

horizontal break

Features:

  • Up to 30 Amps/phase direct (self contained shunt 0.1%)
  • Single-Phase(1Ø) and Three-Phase(3 Ø)
  • The Three-Phase Power Analyzer puts up to 32 measured values on the screen.
  • Broad bandwidth: DC-300kHz
  • Wide input range (0.3V – 1000V, 15mA – 40A).
  • Suitable for frequency inverter drivers
  • Harmonics Analyzer 1-99, Bar charts
  • 0.1% or 0.05% accuracy
  • True Power Measurements, VIcos Ø
  • Wide input range (0.3V – 1000V, 15mA – 40A).
  • RS232 or IEEE 488, Centronics’ printer compatible

Options:

  • Option-01: RS-232 Interface and Centronics printer output including Windows™ software to control, read, and store data
  • Option-02: RS-232- and IEEE-488 Interface, Centronics printer output including Windows™ software to control, read, and store data
  • Option-03: RS-232- and IEEE-488 Interface, Centronics printer output, and 4 analog outputs, 8 analog inputs including Windows™ software to control, read, and store data, read analog inputs
  • Option-03A: RS-232 and IEEE-488 Interface, Centronics printer output 4 analog outputs with provision to also output total power, 8 analog inputs including Windows™ software to control, read, and store data, read analog inputs
  • Option-04: 3-Phase current sensors model 0-100A (supply by 2400), +/- .45% Accuracy
  • Option-05: Operating software under DOS to control 2400, read data and store data via RS-232 or IEEE-488 (National, Keithly Interface)
  • Option-06: 2400 driver for Nat. Instrument LabView
  • Option-07: Standalone software based on LabView
  • Option-07M: Software for Motor Testing
  • Option-07T: Software for Transformer Testing
  • Option-08: TTL-input for external synchronization
  • Option-09: Network to form artificial neutral (mainly frequency inverter measurements)
  • Option-10: 0-300A, 0-3000A flexible current clamps with connector to clamp input of Power Analyzer (1 per phase). 1% 50/60Hz.

Accessories:

  • ACS1: Current clamp with connector to 106A shunt input; 0-200A / 0-1000A, DC-1kHz, 2 %, other ranges and accuracies on request
  • ACS2: Portable printer (106 x 180 x 88mm) with Centronics interface and cable (weight400gr.)
  • ACS3: Soft carrying case for 2400
  • ACS4: Set of test leads, max. 32A, 1.5m (2 red, 2 black)
  • ACS5: Shunt input connector
  • ACS6: Service Manual
  • ACS7: Rack Mounting Kit

Precision Measurements For Any Waveform

Solid performance with user-friendly operation

Valhalla’s 2400 Series Power Analyzers provide high-performance precision in both single and three phases. Unlike other instruments at this price level the 2400 is designed to operate with extreme signals generated on frequency inverter drivers.

Wattmeter, oscilloscope, and power spectrum analyzer in one:

The new 2400 power analyzer measures, computes, and displays all of your critical power variable to let you concentrate on more efficient reliable testing. From the simultaneous and precise voltage and current measurements, you can measure and monitor the power parameters you need and display them in the format that best fits your application.

Extraordinary features:

  • The analyzer inputs are all galvanically isolated.
  • Broad band DC-300kHz.
  • Wide input range (0.3V – 1000V, 15mA – 40A).
  • Exceptional common mode rejection for use in frequency inverter driven systems.
  • The accuracy is 0.1% (0.05% versions are available).
  • The bright LCD monitor displays up to 10 measured values in well legible 9mm high numbers.
  • The Three-Phase Power Analyzer puts up to 32 measured values on the screen.

Variable Display:

You have the choice to visualize wave forms, bar graphs or trend plots. A unique feature of these instruments allows a combination of meter mode and graphic mode.

Computed Values:

Current and voltage: RMS, RM, Peak and Harmonics through the 99th order.
Power: Watts, VA, VAR, and Power Factor
Integrated Measurements: Watt-Hours, VA Hours, VARH and Amp Hours
General values: Frequency, Harmonic Distortion, Crest Factor, Form Factor, and Oscilloscope Display

Simple to use:

Checking power to determine the pertinent power parameters of a frequency inverter driven system is simple. All values display large letters easily read even in dark rooms. The user menu makes operation easy.

Measured values can be:

  • Printed, (Centronics Printer Interface)
  • Sent to a PC via IEEE-488 or RS232 interface
  • Sent to a chart recorder via the analog outputs

You can have all options that we make available installed in your instrument.

Available in six standard configurations:

  • 2410-1S: Single Phase Basic Model, 0.1% accuracy
  • 2410-1HS: Single Phase Power Analyzer,w/Harmonics & Scope 0.1% accuracy
  • 2410-1HE: Single Phase Power Analyzer, w/ Harmonics or Scope, 0.05% accuracy
  • 2430-3S: Three-Phase Basic Model, 0.1% accuracy
  • 2430-3HS: Three-Phase Power Analyzer,w/Harmonics & Scope 0.1% accuracy
  • 2430-3HE: Three-Phase Power Analyzer, w/ Harmonics or Scope, 0.05% accuracy