4314-Ki Wide-Range, Ultra-Safe Digital Igniter Tester

$5,245

Featuring the intrinsically-safe internal circuitry of our storied 4314 igniter tester line, the 4314Ki begins the next generation of precision measurement instruments.

  • Certified Mil Std 810 – Method 511
  • Safe for Explosive & Volatile Atmospheres
  • Complies to EWR 127-1, Section 3.13.8.1
  • Reduced Current (8mA Max)
  • Wide-Range 2-20MΩ
  • 0.1mΩ Resolution
  • Rechargeable Battery-Operated NiMH 10AH
  • Safe 24/7 Continuous Power Mode with Key Switch
  • Fully Controllable Via Serial Interface
  • Certificate of NIST Traceability

Options

Product price: $5,245
Total options:
Order total:
SKU: 4314-Ki Category:

Covering a wide 8-measurement range, the 4314-Ki is an ideal fit for the aerospace, defense, renewable energy, and manufacturing industries.  The 4314-Ki alone replaces multiple instruments while providing clearer, more useful data for applications involving squib circuits, fuses, release mechanisms, thrust vector motor control, deployment systems, pyrotechnic initiators, primers, and generic circuit continuity testing.

18-Hour Battery Life

Powered 4 “D” Cell 1.2V rechargeable NiMH Batteries – Up to 18 hours per charge

Wide Range

With selectable test ranges spanning 2Ω – 20MΩ, the 4314ki is engineered for precision and accuracy across them all.

Dual Power Mode

With optional dual power mode, the 4314ki can be powered by battery or continuous power.

Remote Control

Fully controllable via isolated serial interface RS-232 port on rear.

High Durability

With its Impact-resistant aluminum case, compliant to (EWR) 127-1, Section 3.13.8.1-2, the 4314ki is designed to excel in laboratory and real-world conditions.

Certified Mil Std 810 – Method 511

The 4314ki can be operated wherever your application demands, thanks to its robust manufacturing and design that have been certified Mil Std 810 – Method 511 – safe for volatile and explosive atmospheres.

When the front panel power switch is placed in the OFF/CHARGE position, all power is removed from the output terminals, and the battery pack is connected to the charging circuit. When the switch is placed in the ON position, the battery pack is disconnected from the charging circuit.

The possibility of a common mode voltage between the device under test and AC Power ground is therefore. eliminated. The switch also functions as a low battery indicator. When battery level is within operational limits, the switch will illuminate in blue.

Eight test ranges are only a push of a button away, so you can get more done with fewer instruments. The 4314Ki bypasses this potential error source by providing two terminals of constant current and an additional two terminals for high impedance voltage measurement. The result is a fast, accurate resistance measurement of the load, independent of the resistance of the current carrying leads. The 4314Ki bypasses this potential error source by providing two terminals of constant current and an additional two terminals for high impedance voltage measurement. The result is a fast, accurate resistance measurement of the load, independent of the resistance of the current carrying leads.

The four-terminal configuration of the 4314Ki eliminates errors normally caused by test lead and contact resistances. In many applications, the contact resistance can exceed the value of the load by several orders of magnitude.

The 4314Ki bypasses this potential error source by providing two terminals of constant current and an additional two terminals for high impedance voltage measurement. The result is a fast, accurate resistance measurement of the load, independent of the resistance of the current carrying leads.

As in the past, safety and reliability have been the fundamental focus throughout the conception, prototyping, and testing process. Externally, the unit is housed in a durable, impact-resistant aluminum case built for both laboratory and field use. Internally, the 4314Ki incorporates our redundant fail-safe, current-limiting network circuitry ensuring the instrument test currents cannot exceed the specified amount, even in the unlikely event of a worst-case component failure.

Additionally, the 4314Ki introduces a variety of new features including Dual Power Mode and an Isolated Serial Interface. Dual Power Mode offers the operator either 18 hours of battery life or a 24/7 continuous power mode with the ability to change via a key switch on the rear of the unit. The key switch also acts as an additional safety feature, preventing non-authorized users from changing modes.

The isolated serial interface allows for remote control of the unit through an RS-232 port on the back panel. Digital signals are transmitted across the isolation barrier using iCoupler technology. Via the interface, the user can fully operate the meter and query measurement and configuration data.

Certificate of Calibration Included

An NIST-traceable Z540.3 certificate of calibration is included with every instrument order.  Furthermore, enhanced ISO/IEC 17025 certification is available.

4314 Ki Order Includes

Certificate of Calibration

A fully-documented NIST-traceable Z540 certificate of calibration is included with your instrument.

All Instrument Documentation

Includes user manual, calibration procedures, specifications, and any relevant materials.

Unlimited Phone & Email Support

Our engineering, sales, and customer support teams are always available to answer questions, walk you through particular product features, and assist with any issue that may arise.

Option K 4-Wire Kelvin Test Lead

A set of premium Option K test leads is included with every order, and may be substituted for another set that better suits your needs.

13-Month Comprehensive Instrument Warranty

All pre-paid orders include 13-month instrument warranty that covers component and labor costs in the event of needed repair or recalibration.

Required Power Supply/Battery Pack

Unless you select a different option, every instrument ships with the cables and power supplies required to operate.

Request A Quote

  • This field is for validation purposes and should be left unchanged.

Technical Specifications

Weight 6.2 lbs
Dimensions 11.5 × 9.75 × 3.5 in
Display Type 4 1/2 Digits OLED
Overload Indication Flashes OVERLOAD
Conversion Rate 3 Readings/Second
Terminal Configuration 4-Wire Kelvin
Battery Charger 9VDC at 300mA nominal
Current Source Compliance Clamped at 1.6V
Operating Temperature Range 0°C to 50°C
Power Requirements 4 “D” Cell 1.2V Rechargeable NiMH Batteries 10000mAh
Storage Temperature Range -10°C to 70°C

Range Specifications

Rng # Range Resolution Test Current Failsafe Current Accuracy
1 100µΩ 5mA 8mA ± 0.03% of reading ± 0.02% of range
2 20Ω 1mΩ 5mA 8mA ± 0.03% of reading ± 0.02% of range
3 200Ω 10mΩ 500μA 1.8mA ± 0.03% of reading ± 0.02% of range
4 2kΩ 100mΩ 50μA 180μA ± 0.03% of reading ± 0.02% of range
5 20kΩ 5μA 18μA ± 0.03% of reading ± 0.02% of range
6 200kΩ 10Ω 500nA 1.8μA ± 0.05% of reading ± 0.05% of range
7 2MΩ 100Ω 50nA 180nA ± 1% of reading ± 0.2% of range
8 20MΩ 1kΩ 5nA 18nA ± 2% of reading ± 0.2% of range

 

Documents & Downloads

Here you can download the documentation relevant to your instrument. This section will be continually updated as more media is added (tutorials, demos, etc).

Manual and Specifications

4314-Ki Manual

Quick Contact

Use this form to quickly configure and request a formal quote from our sales department. You may always reach us at 800-548-9806 if you'd like immediate assistance.