Compliant To The Eastern And Western Range (Ewr) 127-1 Range Safety Requirements For Drop Test, including that “These devices shall be analyzed to verify that rough handling, dropping, or single component failure will not result in negating the current-limiting feature.”
NSN 6625-01-460-1499 | Alpha 4314KRC Package
$4,195.00
The Alpha 4314KRC Digital Igniter Tester packaged per NSN 6625-01-460-1499.
Includes:
- Alpha4314KRC-1234
- HCC Carrying Case
- K 4-Wire Kelvin Lead Set
- MP-2 4 Wire Kelvin Mini-Probes
- Battery Charger.
The Alpha 4314 KRC is a configuration of the Alpha 4314 that features reduced test currents.
Rng # | Range | Resolution | Test Current | Fail-Safe Current | Accuracy |
1 | 20Ω | 1mΩ | 5mA | 8mA | ± 0.02% of reading ± 0.02% of range |
2 | 200Ω | 10mΩ | 500μA | 1.8mA | ± 0.02% of reading ± 0.02% of range |
3 | 2kΩ | 100mΩ | 50μA | 180μA | ± 0.02% of reading ± 0.02% of range |
4 | 20kΩ | 1Ω | 5μA | 18μA | ± 0.02% of reading ± 0.02% of range |
Ranges, Resolution, and Accuracy
Rng # | Range | Resolution | Test Current | Fail-Safe Current | Accuracy |
1 | 20Ω | 1mΩ | 5mA | 8mA | ± 0.02% of reading ± 0.02% of range |
2 | 200Ω | 10mΩ | 500μA | 1.8mA | ± 0.02% of reading ± 0.02% of range |
3 | 2kΩ | 100mΩ | 50μA | 180μA | ± 0.02% of reading ± 0.02% of range |
4 | 20kΩ | 1Ω | 5μA | 18μA | ± 0.02% of reading ± 0.02% of range |
TECHNICAL SPECIFICATIONS
Weight | 3 lbs / 1.3kg net; 6lbs / 3kg shipping |
Dimensions | 9.5 × 11 × 3 in |
Display Type | 4 1/2 Digits LED |
Overload Indication | O.L. |
Conversion Rate | 3 Readings/Second |
Terminal Configuration | 4-Wire Kelvin |
Battery Charger | 9VDC at 300mA nominal |
Current Source Compliance | Clamped at 1.6V |
Operating Temperature Range | 0°C to 50°C |
Power Requirements | 4 “D” Cell 1.2V Rechargeable NiMH Batteries 10000mAh |
Storage Temperature Range | -10°C to 70°C |
Maximize Your Instrument’s Performance with Certified-Compatible Cables, Leads, Connectors, & More
-
Power Supply 110-240VAC to 6VDC @ 1.25A
$115.00 -
HDB Rechargeable Battery Set
$305.00 -
R-4 Rack Mount Adapter
$425.00 -
HCC Protective Hard Carrying Case
$605.00 -
K 4-Wire Kelvin Lead Set
$305.00 -
KCS Gold-Plated Kelvin Clips (2 Per Set)
$180.00 -
KK 4-Wire Kelvin Lead Set
$425.00 -
Jaws Heavy Duty Kelvin Clip Set
$180.00 -
K-Gray Shielded 4-Wire Kelvin Lead Set
$365.00 -
KL Heavy Duty 6-ft Kelvin Lead Set (Spade Lug to Jaws)
$425.00 -
MPS Single Pointed Probe Set
$425.00 -
MP1 4-wire Kelvin Micro-Probes (0.05” Spacing)
$425.00 -
MP2 4-wire Kelvin Mini-Probes (0.18” Spacing)
$425.00 -
MP4 4-wire surface probe (1” dia.)
$425.00 -
MP5 4-wire surface probe (0.5” dia.)
$425.00 -
Dual Banana to Dual Banana Lead Set
$305.00 -
K-174
$290.00
Protective Fail-Safe Circuitry
4 Test Ranges
1m Ohm to 19.999k Ohm Capability
4-Wire Kelvin Inputs
Never worry about lead wire length or contact resistance errors requiring redundant calculations with the Alpha 4314’s 4-wire Kelvin inputs.
Battery-Powered Portability
US Military-Approved
US Military-Approved
The Alpha 4314 has been approved by the Department of Defense and all branches of the armed services, including special projects use (i.e. Cruise Missle).
Export Data to PC/Printer/Recorder
Designed with Fail-Safe Circuitry
Countless critical military, aerospace, and industrial applications utilize squibs and other blasting agents, and it is vital that these devices detonate precisely when required – not sooner, not later, not while testing for continuity integrity. To guarantee both the readiness of the device and the safety of the technician or engineer, the Alpha 4314 is equipped with redundant, dual fail-safe, current-limiting network circuitry that ensures instrument test currents cannot exceed the specified amount.
To certify that this level of safety is included in your instrument, we simulate a worst-case component failure during final testing and include the resulting recorded output current flow with your order.
Government and Military Approved
The 4314 series’ circuitry has been reviewed and approved by a U.S. Government Safety Board and all branches of our armed forces for specific military programs (i.e. Cruise Missile).
EWR Drop Test Compliant
Safe for Explosive and Volatile Atmospheres
The Alpha 4314 offers unmatched safety while delivering uncompromising performance and has passed rigorous testing to achieve its status as “Certified Mil Std 810 – Method 511 Safe for Explosive & Volatile Atmospheres.”