2400 Series Wideband Spectrum Power Analyzer
$6,995.00 โ $12,895.00
Precision Measurements for Any Waveform - Wattmeter, oscilloscope, and power spectrum analyzer
High-performance precision in both single and three-phases: a wattmeter, oscilloscope, and power spectrum analyzer in one. The 2400 power analyzer measures, computes and displays critical power variables so you can concentrate on more efficient & reliable testing. The 2400 Series provides simultaneous, precise voltage and current measurements while monitoring and displaying the power parameters you need in the format that best fits your application.
Extraordinary Features
- The analyzer inputs are all galvanically isolated.
- Broad band DC-300kHz.
- Wide input range (0.3V โ 1000V, 15mA โ 40A).
- Exceptional common mode rejection for use in frequency inverter driven systems.
- The accuracy is 0.1% (0.05% versions are available).
- The bright LCD monitor displays up to 10 measured values in well legible 9mm high numbers.
- The Three-Phase Power Analyzer puts up to 32 measured values on the screen.
Voltage | ||||
8 ranges: 0.3 V, 1 V, 3 V, 10 V, 30 V, 100 V, 300 V, 1000 V | ||||
Frequency range | DC, 0.1 Hz โ 1 MHz | |||
Crest Factor | 3:1 at 50 % full scale (fs) | |||
Input Impedance | 1 MOhm | |||
Common Mode | 50 Hz/100 kHz | 160 dB/100 dB | ||
Standard accuracy 23ยฐC; rms, mean, rectified mean; 0.3V typical | Improved accuracy | |||
ยฑ(0.05 % rdg + 0.07 % range) | ||||
1 Hz-1 kHz ยฑ(0.1 % rdg +0.1 % range) | ||||
DC, 1 kHz-10 kHz ยฑ(0.2 % rdg +0.2 % range) | ||||
10 kHz-100 kHz ยฑ(0.3 %/ range + 0.04 % /kHz rdg) | ||||
100 kHz-300 kHz ยฑ(0.3 %/ range + 0.04 % /kHz rdg), typical | ||||
Current | ||||
13 ranges: 1.5 mA, 5 mA, 15 mA, 50 mA, 150 mA, 500 mA, 1.5 A, 5 A; 1, 3, 10, 30, 100 A | Max. 1 A, 5 A, 30 A, resp. | |||
Frequency range | DC, 0.1 Hz-300 kHz / 1 MHz | |||
Crest Factor | 3:1 at 50 % full scale (fs) | |||
Common Mode | 50 Hz/100 kHz | 160 dB/120 dB | ||
Standard accuracy 23ยฐC; 1 A-, 5 A-, shunt input 30 A input | Lowest ranges 1.5 mA, 15 mA, | |||
1 Hz-1 kHz ยฑ(0.1 % rdg + 0.1 % rng) ยฑ(0.1 % rdg + 0.1 % rng)DC, 1 kHz-10 kHz ยฑ(0.2 % rdg + 0.2 % rng) ยฑ(0.7 % rdg + 0.2 % rng)10 kHz-100 kHz ยฑ(0.3 % range + 0.04 %/kHz rdg) ยฑ(0.3 % rng + 0.5 %/kHz rdg), typ100 kHz-300 kHz ยฑ(0.3 % range + 0.04 %/kHz rdg), typical | 1 A: typical. | |||
Improved accuracy 1Hz-400 Hz | ||||
ยฑ(0.05 % rdg + 0.07 % range) | ||||
Power | ||||
104 ranges corresponding to the products V x A. | ||||
Frequency range | DC, 0.1 Hz-300 kHz | |||
45 Hz-65 Hz | PF= 0 to ยฑ0.1 PF= 0 to ยฑ1 PF= 0 to ยฑ1 PF=1 | |||
1 Hz-1 kHz | ||||
DC, 1 kHz-10 kHz 10 kHz-100 kHz(0.1 % rdg + 0.01 % range) | ||||
Add accuracy percentage figures of current and voltage, | ||||
+0.04 %/kHz PF | ||||
Frequency | ||||
0.1 Hz-400 kHz, V triggered; Accuracy ยฑ0.1 %. |
Computed Values | Accuracy; Reactive Power, Var=ยฑ(VA2-W2)1/2, Apparent Power: VA=Arms Vrms; Power Factor: PF=W/VA; Crest Factor: CF=Ap/Arms, Vp/Vrms: Form Factor: FF=At/Arms, Vt/Vrms; Impedance: Z=Vrms/Arms; Total Harm Dist: THD=(Irms2- Ifund2)1/2/Irms
|
Add accuracy percentage figures of values involved in computation. | |||
Integrator | Energy, Charge; Accuracy | Wh, Vah, Varh, Ah; Basic accuracy of integrated quantity. | |||
Harmonic Analysis | Frequency range of fundamental 2.5 Hz-100 kHz | ||||
Range of harmonic | 1-99 | ||||
Accuracy, Harmonic current and voltage 2 Hz-1 kHz ยฑ(0.1 % rdg + 0.1 % range) 1 kHz-10 kHz ยฑ(0.5 % rdg + 0.5 % range) 10 kHz.-100 kHz ยฑ(0.7 % range + 0.1 %/kHz rdg), typical |
|||||
Display | Blue liquid crystal graphic display with FL backlight 64ร120 mm; 128 x 240 pixels
|
||||
Power | AC, 50-400 Hz; Fuse: Power
|
85 V-240 V; 2 A, 15 VA | |||
Dieletric Strength | Inputs to case or power supply Line input to case Input to Input |
2.5 kV/50 Hz/1 minute 1.5 kV/50 Hz/ 1 minute 4 kV/50 Hz/1 minute |
|||
Dimension | H x W x D; Weight | 150 x 235 x 320 mm; 4 kg | |||
Options | IEEE-488-2, RS232, Centronics printer output 4 programmable analog outputs; single-, sum-, or average values 4 analog inputs 0-ยฑ5V, input impedance 200 kฮฉ 4 analog inputs, 0-ยฑ10 V, input impedance 200 kฮฉ Rack Mounting Kit Windows Operating Software 95, 98, 2000, NT, XP; transformer-motor testing |
0-ยฑ5 V, accuracy 0.2 % 0-ยฑ5 V, accuracy 0.2 % 0-ยฑ10 V accuracy 0.2 % | |||
1.5mA-1A Inp/ Shunt Input | 1 A input Hi against ILo Shunt Hi Shunt Lo | 1 A input, mA: 1.5, 5, 15, 50, 150, 500, 1500 Shunt input, mV: 60, 60ร10, 600, 600Vร10, 6000, 6000ร10 Input impedance: 60k |
1 A input: set scaling to 0.1 Shunt input: 60 mV corresponds to 1.0000 A |
Current/Voltage
- RMS
- RM
- Peak
- Harmonics
General
- Frequency
- Harmonic Distortion
- Crest Factor
- Form Factor
- Oscilloscope Display
Integrated
- Watt-Hours
- VA-Hours
- Amp-Hours
Power
- Watts
- VA
- VAR
- Power Factor
Certificate of Calibration Included
An NIST-traceable Z540.1 certificate of calibration is included with every instrument order. Furthermore, enhanced ISO/IEC 17025 certification is available.